No hot water in the apartment: how to find the cause

If there is no hot water in your apartment, first find out whether the whole building is affected: then the cause is planned work, a heating network test or a fault in the heating substation, and the house manager deals with it. If the neighbours have hot water but yours is not coming through or runs barely warm, the fault is usually in the apartment: in the mixer tap cartridge, a valve or your own electric water heater (boiler). Below is the order of checks and the right solution for each case.

Also nights and weekends No hidden fees Diagnostics from €25
Book Now
Illustration: fitting a safety valve under a water heater

Where to look for the cause: quick diagnosis

What you seePossible causeWho deals with it
No hot water in the whole building or areaPlanned work, a hydraulic test or a breakdownHouse manager or the heat supply company
Hot water comes, but you have to run it for a long timeWeak or non-working circulation in the riserHouse manager
Lukewarm water runs from the hot tap, for neighbours on the same riser tooA faulty mixer tap in one of the apartments lets cold water into the hot pipeHouse manager, then mixer tap repair
Hot water is not coming through at one tap onlyCartridge, blocked aerator or filterMixer tap repair
The apartment has its own electric water heater and the water is coldA tripped fuse, thermostat or heating elementWater heater repair
The hot water riser is rusting, leaking or its valve will not closeWorn-out riserHouse manager, riser replacement
Drawing: inside a water heater: heating element, cold inlet and safety valve
Drawing: inside a water heater: heating element, cold inlet and safety valve. Blue: cold water. Red: hot water. Grey: drains.

Shutdown in the whole building: planned work and heating network tests

In summer Rīgas siltums carries out hydraulic tests of the heating networks area by area, and on those days there is no hot water. In 2024 the company explained that a test takes one day, the water temperature may drop as early as the evening before, and the supply is restored on the evening of the same day if no faults are found in the network.

Work inside the building, for example repairs to the heating substation or risers, is organised by the house manager. Look for notices in the stairwell and on the house manager's customer portal; in buildings managed by Rīgas namu pārvaldnieks this is e-parvaldnieks.lv. If there is no notice and the neighbours have no hot water either, report it to the house manager.

The house manager also has a temperature obligation. The rules on sanitary maintenance of residential buildings require the hot water temperature at the outlet of the heat exchanger to be kept at no lower than +55 °C at all times. If the water stays lukewarm throughout the building for a long time, send the house manager a written request and ask for the heating substation to be checked.

Sources: LSM of 03.07.2024 on the Rīgas siltums hydraulic test; Clause 17 of Cabinet Regulation No. 906 of 28.09.2010 (likumi.lv); Rīgas siltums frequently asked questions (rs.lv). Checked on 05.11.2026.

Hot water takes a long time to come: circulation in the riser

In an apartment building, hot water circulates constantly through the flow and circulation pipes so that it comes out of the tap straight away. The hot water supply system is the building's common property, and circulation is provided both in the heating season and in summer.

The building code LBN 221-15 requires that in new and rebuilt buildings hot water reaches the draw-off point no later than 20 seconds after the tap is opened. Older buildings are subject to the standard they were designed under, but 20 seconds is a good benchmark.

If you have to run the water for several minutes, the cause is usually in the building's system: the circulation pump in the heating substation, furred-up circulation pipes or unbalanced risers. Circulation can also be disrupted by a hot water towel rail replacement done without a bypass in one of the apartments. If the problem is only in your kitchen far from the riser, the cause may be a long supply pipe in the apartment.

What to do: measure how long you have to run the water, ask the neighbours and describe it to the house manager in writing. Repairing circulation in the riser is a job for the building, not for one apartment.

Sources: LV portāls e-consultation of 14.07.2021 on hot water circulation; Clauses 18 and 19 of LBN 221-15 (Cabinet Regulation No. 332 of 30.06.2015, likumi.lv); LV portāls e-consultation of 25.04.2025 on applying the standard to older buildings. Checked on 05.11.2026.

Cold water runs from the hot tap: crossflow in a mixer tap

In a single-lever mixer tap, a cartridge mixes the hot and cold water. If the cartridge or the non-return valves of a thermostatic shower mixer are faulty, cold water at higher pressure flows into the hot water pipe. Then lukewarm water runs not only for you but also for the neighbours on the same riser.

  1. 1

    Close the hot water valve

    Find the hot water inlet valve in your apartment and close it. If the valve is very stiff, do not force it.

  2. 2

    Open a hot tap

    Open the hot side of one of the taps. If the water quickly stops running, there is no crossflow in your apartment.

  3. 3

    If the water keeps running

    Cold water is getting into the hot pipe through one of your mixer taps. Close the tap supply valves one at a time to find the culprit.

  4. 4

    Open the valve again

    After the check, open the inlet valve and make sure it does not drip.

If the faulty tap is yours, mixer tap repair or a cartridge replacement costs from €25. If there is no crossflow in your apartment, report it to the house manager: the apartment causing it on the riser can only be found at building level.

Your own electric water heater is not heating

If your hot water comes from your own water heater, check whether it is switched on, whether the indicator light is on and whether a circuit breaker or residual current device has tripped in the fuse box. Also look at the thermostat setting.

Do not unscrew the water heater cover, because there are electrical connections under it. If the RCD trips repeatedly, do not keep switching it back on: disconnect the water heater and book a water heater repair. It costs from €45, and water heater cleaning from €35. The price depends on whether the heating element, thermostat or safety valve has to be replaced and how much limescale has built up in the tank.

When to call a plumber

Replacing a riser section in an apartment costs from €100 per riser within one floor. The riser is common property, so the owners' meeting decides on it and the house manager shuts it off. Read more in the article who pays for riser replacement. For all jobs we agree the price before the work starts.

ServicePriceNotes
Mixer tap repairfrom €25cartridge replacement, leaks, crossflow
Water heater repairfrom €45heating element, thermostat, safety valve
Riser section replacement in an apartmentfrom €100for 1 riser within one floor; materials extra

Frequently asked questions

Sources

Prepared by Santehniķis Rīgā · Page updated 05.11.2026

Book Boiler Repair

After submitting, we contact you within 5 minutes!

⚡

Submit the form - we call you back within 5 minutes!

By submitting you agree to our privacy policy

Book Now